Sign In | Join Free | My disqueenfrance.com
disqueenfrance.com
Kingsine Electric Automation Co., Ltd.
Kingsine Electric Automation Co., Ltd. Specialize in Electric Power Testing
Home > Protection Relay Testing >

K31 Series relay protection tester secondary injection test equipment

Kingsine Electric Automation Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment

K31 Series relay protection tester secondary injection test equipment

Brand Name : KINGSINE
Model Number : K3163i
Certification : ISO9001,CE
Place of Origin : China
MOQ : 1 set
Payment Terms : T/T in advance,L/C
Supply Ability : 50 sets/month
Delivery Time : 15 working days
Contact Now

All-in-One design, Integrated IEC61850 SV & GOOSE, 6I+4V analog channels output, Inbuilt


GPS and IRIG-B, and other advance functions.


◆ Complied IEC61850-9-1, IEC61850-9-2, IEC60044-7/8, etc


◆100/1000Mbit Fiber port for SMV and GOOSE simulations


◆6x35A & 4x310V independent high burden output channels


◆13 channels independent low-level signal outputs


◆ AC/DC measurement (8 channels inputs, 0.1 class, 0-600V/0-5A, auto range)


◆ Transducer calibration (0.02 class)


◆ Energy meter calibration (Mechanical & Electronic meters)


◆ Transient play back up to 3KHz


◆ Lightweight, <18Kg


◆ Fully function KRT software testing modules


◆ 3-Years guarantee of free repair and life-long maintenance


◆ Free software upgrade


Ordering Ref.


ModelCurrent OutputsVoltage Outputs
K31666×35A @ 450VA max / 3×70A @ 850VA max7×130V @ 75VA max
K3166i6×35A @ 450VA max / 3×70A @ 850VA max7×310V @ 90VA max
K31636×35A @ 450VA max / 3×70A @ 850VA max4×130V @ 75VA max
K3163i6×35A @ 450VA max / 3×70A @ 850VA max4×310V @ 124VA max
K31303×35A @ 450VA max4×130V @ 75VA max
K3130i3×35A @ 450VA max4×310V @ 124VA max

Able of what K31 series can test

ItemsANSI® No.
IEC61850 numerical IEDs relay & merge unit
Distance protection relay21
Synchronising or synchronism-check relays25
Undervoltage relays27
Directional Power relays32
Undercurrent or underpower relays37
Negative sequence overcurrent relays46
Overcurrent/ground fault relays50
Inverse time overcurrent/ground fault relays51
Power factor relays55
Overvoltage relays59
Voltage or current balance relays60
Directional overcurrent relays67
Directional ground fault relays67N
DC overcurrent relays76
Phase-angle measuring or out-of-step protection relays78
Automatic reclosing devices79
Frequency relays81
Motor overload protection relays86
Differential protection relays87
Directional voltage relays91
Voltage and power directional relays92
Tripping relays94
Voltage regulating relays
Overimpedance relays, Z>
Underimpedance relays, Z
Time-delay relays


Characteristic


◆ 10 Channels (6x35A & 4x310V) outputs, Each output channels are independent and simultaneous


control of magnitude, Phase angle and frequency values, able to inject DC, AC sine wave and up to


20x harmonics.


◆ Variable battery simulator, DC 0-350V, 140Watts max.


◆ 13 Low-level channels outputs up to 8Vac/10Vdc max.


◆ 0-600V / 0-5A AC/DC measurement in 0.1 class.


◆ Graphical test modules and templates for testing of various relays


◆ Quick relay testing facility in Manual mode


◆ Shot/Search/Check, Point & Click testing


◆ RIO/XRIO import & export facility


◆ Switch on to fault test(SOTF)


◆ Power system model for dynamic testing


◆ Inbuilt GPS and IRIG-B sync end-to-end testing


◆ Online Vector display


◆ Automatic test results assume


◆ Automatic test report creation


◆ Anti-clipping detect, Wrong wiring connect alarm and self-protect, overload and overheat protection


Parameters


Voltage Outputs
Output Range & Power4×310 V ac (L-N)124 VA max each
2×620 V ac (L-L)248 VA max each
3×350 V dc (L-N)140 W max each
Accuracy

AC: <0.03%Rd+0.01Rg Typ.


<0.07%Rd+0.03Rg Guar.


DC: ±10mV @ <5V, ±0.5% @ ≥5V
Resolution1mV
Distortion<0.05%Typ. / <0.1% Guar.
Current Outputs
Output Range & Power6×35A ac (L-N)450 VA max each
3×70A ac (2L-N)850 VA max each
1×100A ac (6L-N)1200 VA max
3×20A dc (L-N)300W max each
Accuracy

AC: <0.05%Rd+0.02Rg Typ.


<0.15%Rd+0.05Rg Guar.


DC: ±5mA @ <1A, ±0.5% @ ≥1A
Resolution1mA
Distortion<0.05%Typ. / <0.1% Guar.
13 Low-Level Channel Outputs
Quantity13 Channels, 16 pin aviation socket
Voltage Outputs RangeAC 0~8V, DC 0~10V
Current Outputs RangeNominal 2mA, 10mA max transient
Output Power≥0.5VA
Accuracy

(0.01~0.8 Vrms):<0.05% Typ. / <0.1% Guar.


(0.8~8 Vrms): <0.02% Typ. / <0.05% Guar.


Resolution0.25mV
Distortion(THD%)<0.05% Typ. / <0.1% Guar.
Frequency & Phase Angle
Frequency RangeDC~1KHz, 3KHz transient
Frequency Accuracy±1ppm
Frequency Resolution0.001 Hz
Phase Range-360°~360°
Phase Accuracy<0.05° Typ. / <0.1° Guar. 50/60Hz
Phase Resolution0.001°
IEC61850 Fiber & GOOSE Ethernet Ports (Optional Function)
Fiber Ports

2 x 100Base-FX Full Duplex, LC type


(Optional to 10/100Mbit, Ethernet RJ45 type)


Fiber Type62.5/125um (Multiple optical fiber, Orange Red)
Wavelength1310nm
Transmit Distance>1Km
Indicator

Spd Green(light): Valid connection


Link/Act Yellow(Blinking): Data exchanging


Note: All hardware of this module are ready for active
Aux. DC Voltage Source (Battery simulator)
Range0~350V @ 140W max
Accuracy0.5%Rg Guar.
Binary Input
Quantity8pairs
Typewet/dry, measurement
Threshold10~600Vdc or potential free, Programmable
Time resolution100us
Debounce time0~25ms (Software Controlled)
Time rangeInfinite
Time errors±1ms @ 0.001~1s, ±0.1% @ >1s
Galvanic isolation4 isolated with each 2 pairs
Binary Output (Relay Type)
Quantity4pairs
Type

Potential free relay contacts, software controlled


Break Capacity ACVmax: 400Vac / Imax:8A / Pmax:2500VA
Break Capacity DCVmax: 300Vdc / Imax:5A / Pmax:150W
Binary Output (Semiconductor Type)
Quantity4pairs
Type:Open-collector, 14 pin Aviation socket
Break Capacity DC

5~15Vdc / 5mA, 10mA max


AC not permit


Response time:100us
Synchronization
Synchronization Mode 

GPS, SMA type antenna connector


IRIG-B, FT3


IEEE1588


Power supply & Environment
Nominal Input Voltage100~240Vac
Permissible Input Voltage85~264Vac, 125~350VDC
Nominal Frequency50/60Hz
Permissible Frequency45Hz~65Hz
Power Consumption1500 VA max
Connection TypeStandard AC socket 60320
Operating Temperature-10℃~55℃
Storage Temperature-20℃~70℃
Humidity<95%RH, non-condensing
Others
PC ConnectionRJ45 Ethernet, 10/100/1000M
Grounding Terminal4mm banana socket
Weight18 Kg
Dimensions(W x D x H)468×375×164(mm)

Additional Information (Optional Modules)


DC Measurement Input (Transducer calibrator)
Voltage InputRange0~±10V dc
Max Input±11V dc
Accuracy<0.02% rg Typ. <0.05% rg Guar.
Input Impedance1Mohm
Current InputRange0~±1mA / 1~±20mA, auto range
Max Input600mA
Accuracy<0.02% rg Typ. <0.05% rg Guar.
Input Impedance15 ohm
AC/DC Measurement Input (Standard meter)
Input Quantity8 channels (blend with binary input pairs)
Voltage range0~600Vrms (Rg:0.1V,1V, 10V, 60V, 600V)
Voltage accuracy<0.1% Rg
Current range0~5Arms(clamp input)
Current accuracy<0.1% Rg
Sample rate10KHz
Input impedance600KΩ
Frequency range45~65Hz, Accuracy < 0.01Hz
Phase accuracy0~360°, <0.2° Typ.
Transient Recorder
Input Quantity8 input channels (blend with binary input pairs)
Recorder timeMax 50 Sec.
Energy Meter Calibration
Sensor UsageMechanical meters / Electronic meters
Sensor OutputHigh lever:>4.5V, Low level:<0.2V
Pulse Input1 pulse input port
Pulse Range500KHz pulse input Max.
Pulse Output1 Transistor output, Open-collector, 5-15Vdc/5mA


Product Tags:

protective relay tester

      

relay protection tester

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

K31 Series relay protection tester secondary injection test equipment Images

Inquiry Cart 0
Send your message to this supplier
 
From:
To: Kingsine Electric Automation Co., Ltd.
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0